Benning 46393 Manual
BENNING World Class Power Solutions THYROTRONIC rectifier range for stationary back up power supply General The protection of electrical load against power failure is often carried out by battery backed up DC power supplies, providing electrical energy to important loads during mains supply, as well as during mains failure. Battery backed up DC power supplies have, over several decades proved extremely reliable and very economical power supplies.
SyPTPro is designed for use with Control Techniques SM-Applications range of option modules onboard Unidrive SP, Affinity, Digitax ST or Mentor MP drives, the software provides a programming environment for high performance motion and PLC functionality. Software or use pre-written software in order to enhance the flexibility of a Unidrive. DPL Toolkit (Windows™ interface) The DPL Toolkit is contained on two diskettes. It is a program which runs in Microsoft® Windows™ Version 3.1x and Windows™ 95. Programs for the UD70 are written on a host PC using the DPL Toolkit. Additional confirmation of SystemWise version 2.2.0, the CTNet Browser version 2.1.1 and the DPL Toolkit version 3.3 has been done at the request of internal Control Techniques users, and are also known to install as expected and to work. Background – The CT Softs were Win-16 VB4 applications created by Control Techniques to assist. Control Techniques Product Marketing Literature. AN0017 Preferred method for emailing a Machine Control Studio software project. AN0128 Copying Drive Parameters. The software provides a full featured programming environment for PLC and motion control onboard Control Techniques AC, DC and servo drives, together with full network configuration for systems combining drives, I/O and operator interfaces. SyPTPro Software Note: Support has been added for the SI-Applications Plus module (Unidrive M700). Control techniques dpl toolkit software for windows 10.
Date Name Success Rate 2009-10-17 06:18:56 30% 2011-09-08 12:27:12 65% 2012-12-12 07:38:53 15% 2012-12-12 07:39:09 0% 2009-10-22 23:46:26 0% 2009-10-23 07:01:19 71% 2009-10-17 06:18:44 20% 2009-10-17 06:18:44 60% 2009-10-17 06:18:44 21% 2009-10-22 23:27:20 0% 2009-10-22 23:27:20 0% 2009-10-22 23:27:20 0% 2011-09-08 10:09:03 0% 2011-09-08 10:09:03 0% 2011-09-08 10:09:03 0% 2009-10-22 23:27:15 0% 2011-09-08 10:01:45 0% 2011-09-08 10:01:45 0% 2009-10-17 06:18:30 79% 2012-12-12 02:03:26 80% 2012-12-12 02:03:28 0%. Arturia analog lab keygen.
• Event storage for the number of charging cycles and other historical data (see operating manual) • programming and read-out of the event memory by means of the service software B_Term 32 784101_01_gb_tebetron_r1.qxd 19:03 Uhr Seite 1.
The reliability of a battery backed up DC power supply is defined by the quality of the battery used, as well as the reliable operation of the rectifier. BENNING World Class Power Solutions THYROTRONIC rectifier range for multi-purpose use Operation Lead-acid and nickel-cadmium batteries achieve optimum service life when remaining on float, in a charged condition. The charger floats the battery in a charged state and also supplies the load with power. In the event of mains power failure the battery will then supply the load its required power. This is called 'parallel operation' (see fig. With substantially discharged batteries, the rectifier unit at first operates in the I-branch of the IU-characteristic line, whereby the charging current. BENNING World Class Power Solutions safe, reliable, powerful Rectifier series Thyrotronic The Thyrotronic series consists mainly of a thyristor-controlled power unit and a microprocessor-controlled monitoring and control unit.
The following main components are included: • mains input with contactor • mains transformer with separate windings • fully controlled 6 pulse three phase bridge with semi conductor protection fuse (working primarily as battery inverse polarity protection) • smoothing chokes and capacitor bank to reduce ripple • control unit with digital setpoint setting • digital monitoring. BENNING World Class Power Solutions THYROTRONIC comprehensive alarm and monitoring concept Functions of the signalling and monitoring unit: In the rectifiers of the Thyrotronic range a very large monitoring concept with the following functions is included as standard: Mains monitoring In case of a mains failure, an electronic regulator block is initiated and the LED and the 'mains failure relay' will be activated. If the mains voltage returns the unit is automatically switched on after a set time. Charger output monitoring The charger output monitoring is a current-dependent low voltage monitoring. BENNING World Class Power Solutions THYROTRONIC technical data Technical data Mains input Input voltage Input current Frequency Power factor Rectifier output Output voltage Output current Output current adjustment range Current accuracy Characteristic Boost voltage Float voltage Equalize voltage (VAC) 230 ± 10% 1-phase 3x400 ± 10% 3-phase (A) see type table (Hz) 50 ±5% ~0.83 at nominal mains voltage and float charging (VDC) 24, 48, 60, 110, 125, 220 (A) see type table (%) 50 – 100 rectifier current limit (%) 0 – 50 battery charging current limit (%) ± 2 IU in acc. DIN41773 @ float and boost.